Came magnetic induction loop detector, 2-channel, 24 V
- Came 2-channel induction loop detector for two loops in the road surface
- Power supply 24 V AC/DC, 2 output relays, LCD display, DIN rail mounting
- The copper wire loops and laying them in the road surface must be arranged separately
Call us, we will help you choose the right part or accessory.
+421 903 628 111Mon–Fri 8–16, also WhatsApp and ViberDescription
The Came SMA2 (009SMA2) evaluates two induction loops laid in the road surface. When a metal vehicle stands on or passes over a loop, the detector switches the output relay and sends a signal to the control unit. Use it with barriers, industrial doors and in car parks.
Functions
- Modes – gate, barrier, closed-circuit or direction logic: output 1 switches when passing from loop 1 to loop 2, output 2 the other way round.
- Outputs – 2 relays (max. 240 V AC / 2 A or 30 V DC / 1 A) and an optional fault output.
- Settings – time functions, 9 sensitivity levels, ASB function for trailer drawbars and 4 frequencies so that detectors do not interfere with each other.
Things to bear in mind before installation
- Location – 35 mm DIN rail in a distribution board or enclosure, protection rating IP20.
- Loop – inductance 20–1000 µH, ideally 80–300 µH, loop resistance including feeder below 8 Ω. The site preparation diagram is in the attachment.
- Feeder – twist the wires at least 20 times per metre. With a cross-section of 1.5 mm², max. 100 m (20–40 µH) or 200 m (over 40 µH).
For a mains power supply there is the 230 V version; for one loop, the Came SMA is enough. An alternative is the Nice LP22. Send any questions to eshop@saver.sk; for wiring in the Košice and Prešov regions, see the section.
Specifications
| Number of channels | 2-channel |
| Power supply | 24 V AC/DC |
| Dimensions | 22,5 × 94 × 88 mm |
| Weight | 300 g |
| Protection rating | IP20 |
| Max. power consumption | 1,5 W |
| Operating temperature | -20 až +60 °C |