  • Came 2-channel induction loop detector for two loops in the road surface
  • Power supply 24 V AC/DC, 2 output relays, LCD display, DIN rail mounting
  • The copper wire loops and laying them in the road surface must be arranged separately
Regular price: Kč6,141.00 −10%
Kč5,526.90Kč4,567.69
Tax includedtax excl. · Kč4,567.69 excl. VAT · Kč5,526.90 incl. VAT
Product availability: In stock – last 1 pcs · orders placed by 12:00 ship today
Collection in our shop at Zborovská 6, Košice

Came G04060 spring for GARD barriers, green, D.50 In stock +Kč1,513.00Kč1,250.41

Came G02807 fixed barrier boom support In stock +Kč2,025.00Kč1,673.55
Total incl. VATTotal excl. VAT

SAVER advisor
Need help choosing?

Call us, we will help you choose the right part or accessory.

+421 903 628 111Mon–Fri 8–16, also WhatsApp and Viber

Description

The Came SMA2 (009SMA2) evaluates two induction loops laid in the road surface. When a metal vehicle stands on or passes over a loop, the detector switches the output relay and sends a signal to the control unit. Use it with barriers, industrial doors and in car parks.

Functions

  • Modes – gate, barrier, closed-circuit or direction logic: output 1 switches when passing from loop 1 to loop 2, output 2 the other way round.
  • Outputs – 2 relays (max. 240 V AC / 2 A or 30 V DC / 1 A) and an optional fault output.
  • Settings – time functions, 9 sensitivity levels, ASB function for trailer drawbars and 4 frequencies so that detectors do not interfere with each other.

Things to bear in mind before installation

  • Location – 35 mm DIN rail in a distribution board or enclosure, protection rating IP20.
  • Loop – inductance 20–1000 µH, ideally 80–300 µH, loop resistance including feeder below 8 Ω. The site preparation diagram is in the attachment.
  • Feeder – twist the wires at least 20 times per metre. With a cross-section of 1.5 mm², max. 100 m (20–40 µH) or 200 m (over 40 µH).

For a mains power supply there is the 230 V version; for one loop, the Came SMA is enough. An alternative is the Nice LP22. Send any questions to eshop@saver.sk; for wiring in the Košice and Prešov regions, see the section.

Specifications

Number of channels2-channel
Power supply24 V AC/DC
Dimensions22,5 × 94 × 88 mm
Weight300 g
Protection ratingIP20
Max. power consumption1,5 W
Operating temperature-20 až +60 °C