-10%
Came Reference 009SMA230 Authorised dealer

Came magnetic induction loop detector, 2-channel, 230 V

  • Came 2-channel induction loop detector with mains power supply
  • Power supply 100–240 V AC, 2 output relays, LCD display, DIN rail mounting
  • The copper wire loops and laying them in the road surface must be arranged separately
Regular price: Kč5,566.00 −10%
Kč5,009.40Kč4,140.00
Tax includedtax excl. · Kč4,140.00 excl. VAT · Kč5,009.40 incl. VAT
Product availability: To order · Available within 14 working days
Collection in our shop at Zborovská 6, Košice

Came G04060 spring for GARD barriers, green, D.50 In stock +Kč1,513.00Kč1,250.41

Came G02807 fixed barrier boom support In stock +Kč2,025.00Kč1,673.55
Total incl. VATTotal excl. VAT

SAVER advisor
Need help choosing?

Call us, we will help you choose the right part or accessory.

+421 903 628 111Mon–Fri 8–16, also WhatsApp and Viber

Description

The Came SMA220 (009SMA230) is a version of the 2-channel loop detector that you power directly from the 100–240 V AC mains. It is suitable where you do not have a 24 V supply in the distribution board. The detector evaluates two induction loops in the road surface and switches the output relay when a metal vehicle is present.

Functions

  • Modes – gate, barrier, closed-circuit or direction logic according to the order in which the vehicle passes over the loops.
  • Outputs – 2 relays (max. 240 V AC / 2 A or 30 V DC / 1 A) and an optional fault output.
  • Settings – with the Mode and Data buttons: time functions, 9 sensitivity levels, ASB function and 4 frequencies.

Things to bear in mind before installation

  • Power supply – 100–240 V AC, 50/60 Hz, power consumption max. 2.9 VA. Only connect it with the power off.
  • Location – 35 mm DIN rail in a distribution board, protection rating IP20.
  • Loop and feeder – inductance ideally 80–300 µH, resistance including feeder below 8 Ω, feeder twisted at least 20 times per metre. The site preparation diagram is in the attachment.

The 24 V AC/DC version is the Came SMA2; for one loop, the Came SMA. You will find barriers in the road barriers category. Send any questions to eshop@saver.sk; for wiring in the Košice and Prešov regions, see the section.

Specifications

Number of channels2-channel
Power supply100–240 V AC, 50/60 Hz
Dimensions22,5 × 94 × 88 mm
Weight300 g
Protection ratingIP20
Max. power consumption2,9 VA
Operating temperature-20 až +60 °C